e01.org

Lightning Rod Conference

848,433 chars · English

The Project Gutenberg eBook of Lightning Rod Conference

This eBook is for the use of anyone anywhere in the United States and
most other parts of the world at no cost and with almost no restrictions
whatsoever. You may copy it, give it away or re-use it under the terms
of the Project Gutenberg License included with this eBook or online
at www.gutenberg.org. If you are not located in the United States,
you will have to check the laws of the country where you are located
before using this eBook.

Title: Lightning Rod Conference

Editor: G. J. Symons

Release date: November 28, 2018 [eBook #58367]

Language: English

Other information and formats: www.gutenberg.org/ebooks/58367

Credits: Produced by Richard Tonsing, Chris Curnow and the Online
Distributed Proofreading Team at http://www.pgdp.net (This
file was produced from images generously made available
by The Internet Archive)

*** START OF THE PROJECT GUTENBERG EBOOK LIGHTNING ROD CONFERENCE ***

Produced by Richard Tonsing, Chris Curnow and the Online
Distributed Proofreading Team at http://www.pgdp.net (This
file was produced from images generously made available
by The Internet Archive)

LIGHTNING ROD CONFERENCE.

REPORT
OF THE
DELEGATES FROM THE FOLLOWING SOCIETIES, VIZ.:

METEOROLOGICAL SOCIETY.
C. BROOKE, F.R.S., _Past President_ [THE LATE].
E. E. DYMOND, F.M.S., _Vice-President_.
G. J. SYMONS, F.R.S., _President_.

ROYAL INSTITUTE OF BRITISH ARCHITECTS.
PROF. LEWIS, F.S.A., _Vice-President_.
J. WHICHCORD, F.S.A., _Past President_.

SOCIETY OF TELEGRAPH ENGINEERS AND OF ELECTRICIANS.
LATIMER CLARK, M. INST. C.E., _Past President_.
W. H. PREECE, F.R.S., M. INST. C.E., _Past President_.

PHYSICAL SOCIETY.
PROF. W. G. ADAMS, F.R.S., _Past President_.
PROF. G. CAREY FOSTER, F.R.S., _Past President_.

CO-OPTED MEMBERS.
PROF. W. E. AYRTON, F.R.S.
PROF. D. E. HUGHES, F.R.S.

_With a Code of Rules for the Erection of Lightning Conductors; and
various Appendices._

EDITED BY THE SECRETARY, G. J. SYMONS, F.R.S.

LONDON: E. & F. N. SPON, 16, CHARING CROSS.
NEW YORK: 446, BROOME STREET.

1882.

KENNY & CO., PRINTERS, 25, CAMDEN ROAD, N.W.

------------------------------------------------------------------------

CONTENTS.

PAGE

PREFACE v

REPORT 1

Section 1.—The purpose which a lightning conductor is intended
to serve 1

Section 2.—A statement of those features in the Construction
and Erection of Lightning Conductors, respecting which there
has been, or is, a difference of opinion, and the final
decision of the Conference thereupon 3

Points 3

Material for Conductor 5

Size of Rod 6

Shape of Rod (Rod, Tube, Tape, Rope, Plait) 7

Joints 10

Protection of Rod 10

Painting 11

Attachment to Buildings 11

Earth Plates 11

Space Protected 12

Height of Upper Terminal 14

Testing Conductors 14

Internal Masses of Metal 15

External Masses of Metal 16

Section 3.—Code of Rules for the Erection of Lightning
Conductors 16

APPENDICES—

A.—Circular and Questions issued to Manufacturers, and their
Replies (1)

B.—Analysis of, and remarks upon, the views of the
Manufacturers (17)

C.—Reply from Manufacturers received after the completion of
Appendix B. (23)

D.—Report of the Representatives of the Royal Institute of
British Architects (27)

E.—Particulars of Accidents by Lightning, collected 1857–59, by
Mr. Symons, and Report upon the same (43)

F.—Abstracts of Printed Documents (51)

G.—Catalogue of Works upon Lightning Conductors (143)

H.—Application to, and Replies from, the Local Hon. Secretaries
of the Society of Telegraph Engineers and other distinguished
Foreign Authorities (175)

I.—General Correspondence (183)

J.—Data respecting the Sectional Area of Metal requisite for
Lightning Conductors (223)

K.—Notes respecting Lightning Conductors, collected in Paris in
May, 1881, by Messrs. Preece and Symons (225)

L.—On the Lightning Conductors at the Paris International
Electrical Exhibition, by Messrs. Dymond and Symons (229)

M.—Miscellaneous (233)

Index to Appendices (245)

ILLUSTRATIONS.

PAGE

Sketch illustrative of terms employed face x

Sketch illustrative of area of protection 13

Plans and Elevation of Nottingham Castle (25)
(26)

Tower of Church of Week St. Mary, Cornwall (32)

Plan and Elevation of Twyford Moors, Winchester (34)

Plan and Elevation of St. James’ Church, West-End, Hants. (35)

Plan and Elevation of houses at Lewisham, Wandsworth, and Forest (38)
Hill

View of Tower of Holborn Union Infirmary, Holloway (40)

Plan and Elevation of Laundry at Gravesend (41)

Regnier’s System of Lightning Conductors (54)

Joints and Earth Terminals recommended in France in 1807 (55)

Powder Magazine, with oblique as well as vertical rods (57)

Mode of attaching Conductor to Upper Terminal (59)

View and Plan of Bruntcliffe Gunpowder Store (75)

View of Board House, at Purfleet (78)

View and Plan of Heckingham Poorhouse (87)
(88)

Diagrams illustrative of space protected (135)
(136)

Plan and Elevation of Church of Ste. Croix, at Ixelles (141)

Sketch of arrangements for Public Buildings in Denmark (177)

Plan and Elevations of Systems for Powder Magazines in Denmark (178)

Attachment and Earth Terminal used in Italy (180)

Sections of Rods used by the Trinity Board (183)

Eddystone and Spurn Point Lighthouses (184)

South Foreland High Light (185)

Eddystone Lighthouse (191)

Plan and Elevation of house at Trolley Bottom, St. Albans (197)

Plan and Elevation of washhouse of Middlesboro’ Fever Hospital (203)

Plan and Elevation of Indian Pagoda (207)

Plan and Elevation of Upwood Gorse, Caterham (211)

Sections of Rod at Upwood Gorse, Caterham (214)
(215)

Sections of Munson’s Rods (216)

View and Section of Cutting’s Conductor Coupling (217)

Plan and Elevation of Christ Church, Carmarthen (218)

Plan and View of house, and of Bootham Bar, York (220)
(221)

PREFACE.

Although France and other nations have taken active steps to give
official sanction to the best known means of protection from the ill
effects of atmospheric electricity, nothing in this way has ever been
done in England for the public generally.

The enquiries by householders and public bodies for advice and
instruction were so numerous, the absence of authorized or well-matured
directions was so marked, the practice in vogue so varied and anomalous,
that it occurred to the Meteorological Society to take some action in
the matter.

Accordingly, at a Meeting of the Council of the Meteorological Society,
held on 15th of May, 1878, it was resolved—

‘That the House Committee be instructed to address the following
Societies:—

THE ROYAL INSTITUTE OF BRITISH ARCHITECTS,
THE PHYSICAL SOCIETY,
THE SOCIETY OF TELEGRAPH ENGINEERS,

asking them to name delegates to co-operate in considering the
desirability or otherwise of issuing a code of rules for the
erection of lightning conductors, and to proceed in preparing a code
if it is thought desirable.’

In accordance with this resolution the following letter was addressed to
the Secretaries of the above Societies:—

THE METEOROLOGICAL SOCIETY,
30, GREAT GEORGE STREET, WESTMINSTER,
_June 14, 1878_.

SIR,

The Council of the Meteorological Society have had under their
consideration for some time the possibility of formulating the
existing knowledge on the subject of the protection of property from
damage by electricity, and the advisability of preparing and issuing
a general code of rules for the erection of lightning conductors.

They are of opinion that this would best be done by a joint
committee of representative members of those Societies before which
such subjects most naturally come; and they have, therefore, decided
upon inviting the co-operation of your Society by the nomination of
one or more delegates to join a Committee by whom the whole question
should be considered, and to whom also any written communications
would be submitted.

The Council trust that your Society may be represented by delegates;
but if that course be impossible, they invite any written
suggestions which you may have to offer.

A meeting of the delegates will be called for an early date after
the receipt from the Societies consulted, of the names of the
gentlemen nominated by each.

We are, Sir,

Your obedient servants,

G. J. SYMONS, }
JOHN W. TRIPE,} _Hon. Secretaries_.

In reply to this circular all the societies invited nominated delegates,
and the Conference was constituted as follows:—

Meteorological Society. │C. BROOKE, F.R.S., _Past
│ President_.

│E. E. DYMOND, F.M.S.

│G. J. SYMONS, F.R.S., _Secretary_.

Royal Institute of British │PROF. LEWIS, F.S.A.
Architects. │

│J. WHICHCORD, F.S.A., _Vice
│ President_.

Society of Telegraph Engineers and │LATIMER CLARK, M. Inst. C.E., _Past
of Electricians. │ President_.

│W. H. PREECE, F.R.S., M. Inst.
│ C.E., _Vice President_.

Physical Society. │PROF. W. G. ADAMS, F.R.S.,
│ _President_.

│PROF. G. CAREY FOSTER, F.R.S.,
│ _Past President_.

The steps taken by the delegates will be best explained by a short
narrative chiefly formed of extracts from the minute book of the
Conference.

The first meeting was held at the rooms of the Meteorological Society,
on November 14th, 1878, when all the delegates were present. Mr. C.
Brooke, F.R.S., was appointed _President_ of the Conference, and Mr. G.
J. Symons, F.R.S., _Secretary_.

Professor W. E. Ayrton was elected a member.

A circular, which will be found in Appendix A, was drafted for issue to
manufacturers of lightning conductors. This was sent to sixty-five
firms, but only eight replied, and their answers are printed verbatim in
the same Appendix. An analysis of the replies forms Appendix B. Appendix
C is a reply received too late for insertion in Appendix A, and after
Mr. Preece had compiled Appendix B. Another reply from an American firm
will be found in Appendix I, p. (192), making ten in all.

At a subsequent meeting, the delegates from the Royal Institute of
British Architects were requested to ask the Council of that body to
issue a circular to their members inviting them to furnish information
respecting buildings injured by lightning. This circular, together with
abstracts of the replies, and a brief Introductory Summary, by Messrs.
Lewis and Whichcord, will be found in Appendix D.

Mr. Symons submitted to the meeting a mass of statistics respecting
accidents by lightning which he had collected in the years 1857–59; they
were referred to Professor Ayrton, and his note upon them constitutes
Appendix E.

At the meeting on August 5th, 1879, the Secretary announced the death of
the President of the Conference, Mr. C. Brooke, F.R.S., a vote of
condolence was passed unanimously, and ordered to be forwarded to Mrs.
Brooke. The Conference then proceeded to elect a new Chairman, and it
was unanimously resolved that Professor W. G. Adams, F.R.S., be
requested to accept the office.

The following circular was approved and ordered to be forwarded to a
large number of the most important newspapers and periodicals throughout
the United Kingdom.

LIGHTNING CONDUCTORS.

_To the Editor of_ ——

SIR,—

In the summer of 1878 delegates were nominated by the following
Societies, viz., the Royal Institute of British Architects, the
Society of Telegraph Engineers, the Physical Society, and the
Meteorological Society, for the following purpose:—

“To consider the possibility of formulating the existing knowledge
on the subject of the protection of property from damage by
electricity, and the advisability of preparing and issuing a
general code of rules for the erection of Lightning Conductors.”

The delegates have held several meetings, and have already
collected, firstly, from the manufacturers of Lightning Conductors,
and secondly, from the Members of the Royal Institute of British
Architects, a large amount of thoroughly practical information.
Several of their number are also engaged in forming abstracts of the
salient features of the literature of the subject.

The Members of the Conference are, however, most anxious that their
Report should be as trustworthy and as exhaustive as possible, and
they have, therefore, instructed me to ask you to assist them by
publishing this epitome of their proceedings, and allowing them to
invite correspondence upon the points mentioned below.

I am, Sir,
Your obedient servant,
G. J. SYMONS, F.R.S.,
_Secretary to the Conference_.

LIGHTNING ROD CONFERENCE,
30, GREAT GEORGE STREET, S.W.

CLASS OF FACTS MOST REQUIRED.

Full details of accidents by lightning, stating especially whether
the building struck had a conductor or not. If there was a
conductor, state its dimensions—construction—mode of attachment to
building—whether its top was pointed—distance of its upper terminal
from the place struck—nature and extent of the connection between
the conductor and the earth, and whether the earth was dry or
moist—whether the conductor was itself injured—and whether the
conductor or the point struck was the most salient object in the
vicinity. Information is also desired, either verbally or by
sketches, as to the position of metal spouting and lead roofing
relatively to the point struck, and to the conductor.

Details of the thickest piece of metal melted by a flash of
lightning are much needed.

Unimpeachable evidence of the failure of conductors is much desired,
as such failures would be extremely instructive.

The replies were by no means as numerous as was expected: the most
important will be found in Appendix I.

At the meeting, October 27th, 1879, it was resolved “That the members of
the Conference will undertake to prepare abstracts of the principal
English and Foreign books upon Lightning Conductors.” This work became
extremely heavy, and occupied much time, as will be seen from Appendix
F, which contains abstracts of sixty separate treatises, of which 26 are
from English, 17 from French, 6 from Belgian, 5 from American, and 5
from German authors, and one is from the Norwegian.

In order to guard against omitting important works, it was resolved
“That application be made to the Society of Telegraph Engineers for
advance sheets of the Ronalds Catalogue.” From it, supplemented by Mr.
Latimer Clark’s and other lists, the Secretary compiled Appendix G.,
which contains the full titles of no fewer than 704 separate works upon
lightning conductors, or on subjects intimately connected therewith.

At the same meeting it was resolved that efforts be made to obtain a set
of the official instructions issued in all foreign countries. The
circular issued, and an abstract of the information collected, including
replies from America, Belgium, Denmark, Germany, Holland, India, Italy,
and Norway, will be found in Appendix H. Full details respecting the
practice in France will be found in Appendices F, K, and L, and a notice
of Zenger’s Austrian system, on p. (104).

At the meeting, Nov. 20th, 1879, the Secretary was unanimously requested
to act as Editor of the Report.

At the meeting, Jan. 22nd, 1880, a letter was received from Mr. R. H.
Scott, F.R.S., _Secretary to the Meteorological Council_, enclosing a
report respecting the injury to the “Southern Queen,” it was resolved,
“That some of the delegates visit the ship.” The report and a note of
the results of the visit will be found in Appendix I page (205).

At the meeting, April 15th, 1880, Prof. D. E. Hughes was unanimously
elected member of the Conference.

At the meeting, July 6th, 1880, the Secretary handed in a sketch of a
house with various parts of the lightning conductor marked upon it, and
obtained from the delegates definite names for each portion, in order
that in framing the report there might be no uncertainty as to what was
meant by any special term, great confusion in this respect having
previously existed.

The terms adopted have been: _Conductor._—The whole arrangement for the
protection of a building. _Point._—The upper termination of the
conductor, whether blunt or sharp, single or bifurcated. _Upper
terminal._—That portion of the conductor which is between the top of the
edifice and the point. _Joint._—Any connection between any two parts of
the conductor. _Rod._—The main portion of the conductor, whether it
consist of rope, tape, tube or solid rod. _Circuit des Faîtes._—A rod
running round the eaves of a house, the battlements of a tower, &c.
_Earth plate._—The termination of the conductor in the ground, the
pattern being indicated by special terms.

The accompanying lithograph will, it is hoped, supply all additional
necessary particulars.

It is desirable to state that the illustrations in this Report have been
prepared by Mr. E. White Wallis, F.M.S., so as to bring out the various
features distinctly, and as nearly as possible in true proportion, but
without any attempt at artistic finish.

The meetings during the latter part of 1880, and the early part of 1881,
were devoted chiefly to the discussion of various questions as bases for
the report. Much time was also occupied in perfecting the various
appendices, and in compiling an exhaustive index to them.

In May, 1881, Messrs. Preece and Symons, being in Paris, made careful
enquiries as to the existing practice in France respecting lightning
conductors. Their notes form Appendix K.

At the meeting held on May 27th, 1881, the Secretary was instructed to
draw up a draft report, and this having been put in type was sent to all
the delegates; carefully considered, revised, and amended at various
subsequent meetings, and finally adopted.

[Illustration:

INDEX SKETCH OF LIGHTNING CONDUCTOR, ILLUSTRATING THE TERMS EMPLOYED
IN THE REPORT.
]

TERMS APPLIED TO THE VARIOUS
PARTS OF A CONDUCTOR.

_Ⴤ_ _Crutch_
⊞⬜⊞ _Strap_
⋂ _Staple_
⚲ _Wall Eye_
A _Point_
B _Upper Terminal_
c _Joint_
D _Rod_
E _Ridge Rod_
F _Circuit des faîtes_
G _Earth Plates_
G^1 _Earth Plates Sanderson_
G^2 _Earth Plates Borrel_
G^3 _Earth Plates Spang_

REPORT.

The Delegates are of opinion that it will conduce to clearness of
statement if their Report be divided into three sections—

(1) The purpose which a lightning conductor is intended to serve.

(2) A statement of those features in the construction and erection of
lightning conductors respecting which there has been, or is, a
difference of opinion, and the final decision of the Conference
thereupon.

(3) Code of rules for the erection of lightning conductors.

SECTION I.—_The purpose which a Lightning Conductor is intended to
serve._

A flash of lightning is the passage of an electric spark between two
bodies oppositely or unequally electrified, and between which the
difference of electric pressure or potential is sufficiently strong to
break across the air space which separates them, and to produce what is
known as a disruptive discharge. A flash may pass either between one
cloud and another, or between a cloud and the earth. In the former case
damage is not likely to be done, in the latter damage is or is not done,
according to the point at or from which the lightning strikes. The more
any object projects above the general level, the less is the distance
between it and the cloud, and as the less the distance the less the
resistance offered to the discharge, high objects are, _cœteris
paribus_, most frequently struck. Some substances, such as copper or
iron, can conduct a large quantity of electricity with facility, and are
called good conductors. Other substances, such as living vegetable or
animal matter, offer much obstruction, and form only partial conductors;
while dry earth, stone, and wood almost entirely prevent the passage of
electricity, and are very bad conductors—in fact, insulators.

For instance, a man may with perfect impunity clasp a copper rod an inch
in diameter, the bottom of which is well connected with moist earth,
while the top of it receives a violent flash of lightning. But if the
electricity does not find a path prepared for it, it will utilise such
partial conductors as may be reasonably near, for example—the heated air
from a kitchen chimney, the soot inside, and then the metal range at the
bottom; here, however, stone or dry material is generally found, which
will not conduct it, and then it dashes across the kitchen at some gas
or water pipe, or some pump or drain leading to damp earth, doing
serious damage on the way: or it may meet some tree in its course and
rend it from top to bottom, and if the human body intervene life may be
destroyed. Mechanical injury is inflicted only where the conduction for
the discharge is imperfect.

A lightning conductor fulfils two functions: it facilitates the
discharge of the electricity to the earth, so as to carry it off
harmlessly, and it tends to prevent disruptive discharge by silently
neutralising the conditions which determine such discharge in the
neighbourhood of the conductor.

To effect the first object a lightning conductor should offer a line of
discharge more nearly perfect, and more accessible, than any other
offered by the materials or contents of the edifice we wish to protect.
To effect the second object the conductor should be surmounted by a
point or points. Fine points and flames have the property of slowly and
silently dissipating the electrical charges; they, in fact, act as
safety valves.

If all these conditions be fulfilled; if the points be high enough to be
the most salient features of the building no matter from what direction
the storm cloud may come, be of ample dimensions and in thoroughly
perfect electrical connection with the earth, the edifice with all that
it contains will be safe, and the conductor might even be surrounded by
gunpowder in the heaviest storm without risk or danger.

All accidents may be said to be due to a neglect of these simple
elementary principles. The most frequent sources of failure are
conductors deficient either in number, height, or conductivity, bad
joints, or bad earth connections. There is no authentic case on record
where a properly-constructed conductor failed to do its duty.

SECTION II.—_A Statement of those features in the construction and
erection of Lightning Conductors, respecting which there has been, or
is, a difference of opinion, and the final decision of the Conference
thereupon._

Points.
Material for Conductor.
Size of Rod.
Shape of Rod.
(Rods, Tubes, Tape, Rope, Plait.)
Joints.
Protection of Rod.
Attachment to Building.
Earth Plates.
Space Protected.
Height of Upper Terminal.
Testing Conductors.
Internal Masses of Metal.
External Masses of Metal.

=POINTS.=—Starting with the extreme top, we have first to deal with the
question of points. The utility of points was hotly contested rather
more than a century since, and an abstract of the discussion will be
found in Appendix F, page (79), and difference of opinion still exists
as to their precise functions and value. The decision as to the best
form of points is complicated by two opposing requirements (1), the
sharper the point the more rapid the silent discharge of electricity,
and, therefore, the more effective the conductor; but (2) the sharper
the point the more easily is it destroyed by oxidation, or fused, should
a heavy disruptive discharge fall upon it.

Attempts have been made by the use of gold, silver, and platinum, to
obtain a sharp point which should not only be durable, but, owing to its
high melting point, resist fusion by a disruptive discharge. But such
metals are very expensive, and the statements in Appendix F, pages (67,
69, 73, 103, 123, 128, and 139) prove that even platinum points are
often damaged. Copper points whose sectional area is less than ·05 of a
square inch are very liable to be melted. Lightning has even fused a
copper rod ·10 sq. in. in sectional area, _i.e._, 0·35 in. in diameter,
and there are many rods still standing of which the extremity has been
melted into a button or knob.

For these reasons it seems best to separate the double functions of the
point, prolonging the upper terminal to the very summit, and merely
bevelling it off, so that, if a disruptive discharge does take place,
the full conducting power of the rod may be ready to receive it, and,
therefore, that there may be no risk of melted particles of metal
setting fire to the building, as has occurred. [Appendix F, p. (93).]

At the same time, having regard to the importance of silent discharge
from sharp points, we suggest that at one foot below the extreme top of
the upper terminal there be firmly attached, by screws and solder, a
copper ring, bearing three or four copper needles, each 6 inches long
and tapering from ¼ inch diameter to as fine a point as can be made; and
with the object of rendering the sharpness as permanent as possible, we
advise that they be platinized, gilded, or nickel plated.

Vanes, finials, and ornamental ironwork so frequently form the upper
portion of edifices, that it is essential to consider their relation to
the conductor. They should always be in perfect metallic connection with
the conductor. The possibility of such metal work inducing the charge to
desert the conductor for some other path is sometimes suggested, but it
could not happen unless the conductor were out of order, _e.g._, of
inadequate conducting power, or had an imperfect earth-contact.

With respect to factory chimneys, a different practice prevails in
England from that which is nearly universal on the Continent. In this
country one straight rod is usually carried up on one side of the
chimney to a height above the top about equal to the diameter of the
chimney. On the Continent two arches of iron are put crosswise over the
aperture of the chimney, and a vertical rod is carried up from the
intersection. In both systems the upper terminal suffers from the
corroding effect of the fumes from the chimney. Dr. Mann thought,
Appendix F, p. (132), that considering the ready path for lightning
afforded by the heated smoke discharged from chimneys, a coronal
conductor should be placed upon them, as well as a multiple point.
Messrs. Gray say, p. (9): “For high chimney shafts we fit a copper band
round the top, and four points thereon connected to main down rod.” The
Edinburgh Gas Works chimney, 341 feet high and 14 feet across at the
top, was fitted with a conductor under the advice of Faraday, Appendix
F, p. (89). It had an iron plate on the top; Faraday directed that the
rod should be connected with this plate, and the upper terminal should
rise vertically 6 feet above it.

We are of opinion that a coronal or copper band, with stout copper
points, each about 1 ft. long, at intervals of 2 or 3 ft. throughout the
circumference, will make the most durable and generally useful protector
for a factory chimney, but these points should be gilded or otherwise
protected against corrosion.

=MATERIAL FOR CONDUCTOR.=—Iron and copper are practically the only two
metals which need consideration; brass, which has sometimes been used is
so perishable that its employment is a self-evident error. We will
assume the conductivity of equal lengths and weights of iron to be, in
the case of steady currents of electricity, ⅙th that of copper, and the
cost of iron to be ⅑th that of copper, this would make the cost of
copper for equal conducting power ^9⁄_{6}ths, or 50 per cent. dearer
than iron. But there are other matters to be considered: (1) the great
weight and bulk of iron rods; (2) their deterioration by rust; (3) the
serious obstruction offered by a rusty joint; (4) the suddenness of
lightning discharge which modifies the conductivity; and lastly, that
iron is so much more rigid than copper that (except in the form of iron
wire rope, of which we shall speak hereafter) it can rarely be used in
greater lengths than 20 feet, and thus numerous joints become necessary,
whereas every needless joint should be avoided.

As regards galvanizing, we think it scarcely judicious to trust entirely
to it for protection against oxidation, for many instances of imperfect
galvanizing have come to our knowledge.

On the other hand copper becomes brittle, not only when exposed to the
air, but also by the passage through it of powerful charges of
atmospheric electricity. Franklin used iron, and it is employed in
America and on the Continent much more generally than copper, and it is
less tempting to the thief.

Nevertheless, as the cost of erection bears a considerable ratio to the
cost of the rod itself, and as iron possesses the disadvantages above
stated, we think that in all ordinary cases a copper rod will in the end
prove the cheapest, as it will certainly be the most durable.

=SIZE OF ROD.=—This is perhaps the most difficult subject which has to
be determined. We greatly regret the shortness of Table I. in Appendix
K; but we think that it must be assumed from it that lightning has fused
a copper rod ·10 in. (⅒th) in area, _i.e._, weighing 6 ounces to the
foot. We have also the Caterham case, Appendix I, p. (214), where a
copper tube weighing 5¾ ounces per foot was heated to redness.

The saving of cost which might be effected by using, for very low
buildings, rather slighter rods than for ordinary edifices is not worth
considering. In a 30 feet rod it could hardly amount to 10s. We
therefore recommend as the _minimum_ to be used:—

Material. Pattern. Diameter. Sectional Area of Metal. Weight per foot.
in. sq. in.
Copper Rope ½ ·10 6 oz.
Copper Round Rod ⅜ ·11 7 oz.
Copper Tape ¾ × ⅛ ·09 6 oz.
Iron Round Rod 9/10 ·64 35 oz.

=SHAPE OF ROD.=—This depends upon a subject which until lately was
warmly discussed, viz., upon the relative importance of the sectional
area, and of the superficial area of a conductor; a matter which has
been the subject of active discussion among electrical authorities.
Faraday and Sir W. Snow Harris, for example, held diametrically opposite
views respecting it. [Appendix F, p. (89), and I, p. (195).]

There is abundant and conclusive evidence that in the case of steady
electric currents, conductivity depends upon sectional area alone, and
not at all upon extent of surface, and experiments by Mr. Preece and Dr.
Warren De la Rue tend to show that, in the case of sudden discharges
from condensers, to which lightning discharges are probably analogous,
the influence of form is not considerable. On the other hand, there is
equally conclusive evidence that the facility with which currents of
short duration pass through conductors is affected by the form and
arrangement, as well as by the sectional area of the conductors. Upon
the whole we agree with the opinion quoted below, from a writer
recognized in the United States as a high authority on lightning
conductors, who, after describing and engraving more than fifty patterns
of rods, says[1]:—

Footnote 1:

Spang, “A Practical Treatise on Lightning Protection,” p. 121.

“The alleged improvements in the said conductors are, in nearly all
cases, worthless, or of a trifling and unimportant character. The
fact is, the said conductors are quite inferior, and contain no
essential improvement upon the ordinary round iron rod used during
the days of Franklin.”

In Europe the only forms at all generally employed are:—

Rods (round or square); Tubes; Tape; Ropes (wire, or wire with hemp
centres); Plait.

=Rods= (round or square).—The advantages and disadvantages of rods are
easily stated. The advantages are their durability and their rigidity,
the latter being of importance for long upper terminals. The
disadvantages are the necessity for numerous joints, and the difficulty
of avoiding serious disfigurement to the building to which they are
attached.

=Tubes= have much the same merits and demerits, with the additional
objection that they are necessarily of larger diameter than solid rods,
and therefore more conspicuous. They have also an additional
disadvantage in that they are generally joined together by screw
collars. The cutting of the thread in the tube seriously diminishes the
sectional area, and the joint so made is electrically defective. If
tubes are used, the joints should be made as directed in the code of
rules under the head of joints.

=Tape= is a form of rod which is of comparatively recent introduction,
and possesses many advantages. Foremost among these is the length which
can be supplied in a single piece. Where, as at the junction with an
upper terminal, a joint is needed, it is easily made by clamping or
rivetting the two surfaces together and then imbedding the whole in a
mass of solder. No kind of coupling known to us is, in our opinion,
equal to this very simple one. Owing to the flexibility of the tape it
can be made to follow closely the outlines of a building, or may be
countersunk in it, and painted over, but, as stated further on, abrupt
bends should be avoided, and the precautions and instruction set forth
on page 18 should be followed. The objections to tape, Appendix A, pages
(5) and (16) will be found to be objections, not to tape _per se_, but
to bad practice on the part of some persons who have fitted it up and
availed themselves unduly of its flexibility.

=Ropes.=—For many years past rope constructed of twisted strands of
copper or of iron wires has been largely employed for lightning rods.
There is on record a very remarkable case of the complete destruction of
a brass wire rope, an event which, if it had been repeated, might justly
have been regarded as a serious objection to the use of ropes. This case
is fully reported in Appendix F, pages (62–63); and from it some French
electricians have concluded that lightning may single out some wires
from a rope and travel along them in preference to the rest, even when
the whole of them are hardly sufficient to give it a free passage.
Whatever may have been the explanation, this accident seems to be
unique, and even if we accept the explanation given, the only extra
precaution which it calls for, is the soldering of each extremity of the
several wires forming the rod, and at every joint, into a single mass.

We agree with M. Borrel in thinking that serious evil arises from using
wire of too small diameter, which involves an additional number of
interstices for the lodgement of dirt, smoke, and water, and at the same
time renders the wires too thin effectually to resist oxidation. We have
had before us rope ⅜ in. in diameter, composed of 49 strands of a copper
wire about No. 19 B.W.G., say 0·04 in. in diameter. On the contrary, one
firm speaks of employing No. 10 B.W.G., _i.e._ 0·14 in. diameter, and in
special cases Nos. 8 and even 7, which would be about 0·17 in. and 0·19
in. diameter respectively: these would not be open to the objection we
have raised.

The objection to thin wires is necessarily greater with iron ropes, even
if galvanized, than with copper, for irrespective of the doubt as to the
perfect galvanizing of every part, there is the greater brittleness, and
consequent risk of damage from defective continuity.

=Ropes with Hemp Centres.=—One English firm sent us a specimen of
6–strand copper rope with a hemp core, and we understand that the same
pattern is occasionally used both in iron and copper in France. We do
not know the precise object aimed at—probably flexibility—but
considering the perishableness of such a core, its variation in length
with the hygrometric state of the air, and its invariability when the
copper is varying with temperature, we cannot regard it as a wise
construction.

=Plait.=—This form of rod was probably designed in the belief that the
essential element in a lightning rod was plenty of surface. It is made
in two sizes, with copper wire, about No. 16 B.W.G., plaited into a sort
of ribbon. It invites oxidation as much as is possible, and is in our
opinion neither durable nor trustworthy. The original form of this rod
was ridiculously bad; for it consisted of 13 copper wires and 1 zinc
one. Every time that it became wet, feeble electric action was set up,
and the zinc wire was gradually destroyed, without the slightest benefit
to anybody.

=JOINTS.=—The most fruitful sources of danger in rods are _bad joints_,
not necessarily those that are mechanically bad, but those that are so
electrically. A joint is said to be electrically bad when it offers
resistance to the passage of electricity through it. _There should be no
resistance whatever._ A careful inspection by Capt. Bucknill, R.E.
(Appendix M, p. 243), has proved that bad joints in lightning rods are
very abundant, though they appear perfectly sound; and everyone who has
measured the electrical condition of conductors confirms this fact. Bad
joints have the same effect as lengthening the conductor; and, in one
case, one bad joint was found to have the same effect on a discharge of
electricity as a conductor 1,900 miles long. It is evident that such
rods may be worse than useless, for other parts of the building may
offer easier paths for the discharge to the earth. If the joint be
imperfect, and the rod convey a charge to earth, heat will be generated
at the joint, the rod may be fused, and the discharge be diverted to the
building.

Screwed, scarfed, and rivetted joints, however well they may be made
mechanically, are certain to rust and corrode in time, owing to the
expansions and contractions due to changes of temperature admitting
moisture, and thus causing corrosion and resistance. No joint can
possibly be electrically perfect that is not _metallically continuous_,
and careful soldering, in addition to screwing, scarfing, or rivetting,
is the only certain mode of securing this. Soldering is a method that
has borne the test of experience, and its success as a means of securing
perfect joints leaves no excuse for its omission. The fewer joints the
better, but where there are joints they can only be made electrically
secure by careful soldering.

=PROTECTION OF ROD.=—The lower part of copper rods is sometimes stolen
for the sake of the metal. This can be guarded against by putting it
inside a length of iron gas-barrel, extending from some distance below
ground to 10 ft. above it.

=PAINTING.=—Iron conductors, even if they are galvanized, should be
painted throughout, except at the points, which should be gilded or
nickel-plated.

In France and Belgium painting is resorted to to a considerable extent,
and the practice was recommended by the late Professor Joseph Henry, and
followed very largely in America. [Appendix F, pages (99) and (113).]

=ATTACHMENT TO BUILDINGS.=—The evidence against the use of glass or
other material in order to insulate the conductor, is overwhelming, and
insulation may be regarded as unnecessary and mischievous. The
essentials are (1) that the rod be attached to the building by
fastenings of the same metal as itself, (2) that the fastenings be of
adequate strength, (3) that they be of such form as not to compress or
distort the rod, (4) that they allow play for its expansion and
contraction, (5) that they hold it firmly enough to prevent all the
weight falling on any one bearing.

Where practicable it is well to take the rod down that face of the house
which is most exposed to rain.

=EARTH PLATES.=—This portion of the lightning conductor is of the utmost
importance, but has hitherto been the most neglected. The majority of
cases in which lightning has caused injury very near to or upon
conductors are traceable to those conductors having imperfect earth
terminals. We know of many cases in which the earth terminals have been
miserably imperfect, or entirely neglected, when the above-ground
portion has been perfectly satisfactory. In fact, though it may be
admitted that the case found by Dr. Mann,[2] of the lightning rod of a
church tower, the lower end of which was thrust into an empty glass
bottle, is an exceptionally bad one; yet there are sadly too many, of
which the Middlesboro’ case, Appendix I, page (217) is a perfectly fair
type.

Footnote 2:

Quarterly Journ. Met. Soc., Vol. II., p. 420.

A convenient earth connection is often afforded in towns by the iron
mains for gas and water—arguments both for and against the utilisation
of both water and gas mains will be found in the Appendix—we, therefore,
need only state our opinion in favour of connection with both. But no
connection should ever be made with soft metal pipes, because of the
risk of their fusion; and the conductor should be kept as far as
possible from internal gas pipes on account of the risk of lighting the
gas at an imperfect joint.

As a general rule we advise the soldering of a plate of metal, copper to
copper, iron to iron, to the lower end of the conductor. The earth plate
should always be of the same metal as the rod, otherwise destructive
galvanic action sets in. This plate, which may be flat or cylindrical,
must not have less surface than 18 square feet, _i.e._, 9 square feet on
each face; there is no advantage in notching or pointing it. A hole must
be dug, or well sunk, to receive this plate, and the hole must be so
deep that the earth surrounding the plate shall _never_ be dry. Any
available drain or other water should be allowed to soak into the earth,
over the site of the plate. After the hole has been dug, and the plate
lowered into position, it should be filled with cinders, or coke. In
extremely dry rocky localities, it is sometimes impossible to fulfil
these conditions: then the best thing to do is to bury three or four
hundredweight of iron at the foot of the conductor, still using the
earth plate and the coke, and taking especial care that the rain-water
and sink pipes discharge over it.

All drains, water-courses, in fact, everything which will assist in
distributing the charge over a large extent of moist earth should be
utilized by leading branches from the earth plate to them, or a long
length of the rod may be laid in a drain if it be one which will be
constantly wet.

=SPACE PROTECTED.=—The question as to the extent of the space which will
probably be protected by a lightning rod is one which is of very great
practical importance, because it governs the number and height of the
upper terminals which are required for the protection of any given
building. The index to the Appendix shows that “Protection, Area of,” is
discussed upon twenty-nine pages in different parts of the Appendix. It
has been laid down that the space protected was a cone, having the point
for its apex, and a base whose radius was equal to twice the height of
the point, while the latest French official instructions, Appendix F, p.
(67), state that a point will “effectively protect a cone having the
point for its apex, and a base whose radius is 1·75 of its height.” The
English War Department instructions considerably reduce this space by
asserting, Appendix F, p. (71), that “no precise limit can be fixed to
the protecting power of conductors. In England the base of the protected
cone is usually assumed to have a radius equal to the height from the
ground; but though this may be sufficiently correct for practical
purposes, it cannot always be relied upon.”[3]

Footnote 3:

On page (96) two instances are recorded in which, if the evidence can
be trusted, the stroke fell within a radius equal to the height, but
it is only right to say that the facts are not very clearly recorded.

[Illustration: Sketch illustrative of area of protection]

According to this rule, the church of Ste. Croix (see Appendix F, p.
(141)), would require four upper terminals, one on steeple, one on
chancel, and one in the middle of each half of the transept.

From theoretical considerations stated by Mr. Preece, Appendix F, p.
(137), he arrives at the conclusion that “A lightning rod protects a
conic space whose height is the length of the rod, whose base is a
circle having its radius equal to the height of the rod, and whose side
is the quadrant of a circle, whose radius is equal to the height of the
rod.”

At present we have not sufficient data to enable us theoretically to
calculate the space protected by a lightning rod, and therefore we are
compelled to draw up our rules upon the question entirely from
experience, and here we find, that with the doubtful exceptions already
mentioned, there is no recorded instance of a building being struck by
lightning within a conical space, the radius of whose base was equal to
its height, and we think that the adoption of this rule may reasonably
be expected to yield that security in the future, which as far as we
know, it has done in the past.

=HEIGHT OF UPPER TERMINAL.=—This matter is one which may be left
entirely to the option of individual architects and engineers, subject,
of course, to the opinions expressed under the heading “Space
Protected.” In France extremely long _tiges_, or upper terminals,
generally 33 feet long, are used; but it is obvious that they are
necessarily very strong and heavy, and both by their weight and by the
great leverage which they exert when there is any wind, they must
produce serious vibrations in the roof. In England hitherto the opposite
error is almost universal, and we seldom see a conductor carried high
enough to protect all the building to which it is attached. The question
of appearance comes in here, but concerning it we need only remark that
while in England care seems generally taken to conceal the conductors,
in France they are, to a certain extent, made features of the edifice.
With a proper exercise of taste, the terminals of the lightning
conductors can be made to assist the ornamentation of the building, as
has been done in many cases.

=TESTING CONDUCTORS.=—Periodical examination and careful testing of the
lightning conductor are requisite to maintain the system in efficient
order. Points will corrode from oxidation and fusion; joints will get
loose and bad through the action of weather and workmen; connections
will decay both above and below ground; imperfections will develope
themselves; alterations will be made by landlords and tenants; and, in
spite of every precaution during erection, the conductor will thus lose
its efficiency if it be not _maintained_ in thorough order. For this
purpose inspection should be both visual and electrical. In order to
facilitate the electrical examination of the conductor, some firms have
erected a double rod, connected with one upper terminal, one on each
side of a chimney or shaft; this is a very efficient arrangement, for it
provides a means for testing from the ground. It has also been proposed
to carry an insulated wire alongside or even within the rod, connected
to the terminal at the top, and to the testing apparatus at the bottom.

A testing apparatus has been devised by Mr. Anderson (_Lightning
Conductors_, p. 60). M. Borrell, Appendix K, p. (226), Captain Bucknill,
R.E., Appendix M, p. (244), and Mr. Vyle, Appendix M, p. (244), have
also introduced apparatus for the purpose. The system in use in Paris,
Appendix K, p. (225), and M, p. (245), is perhaps the simplest and
cheapest, and is effective as regards testing the efficiency of the
conductor, but not that of the earth connection.

The efficiency both of the conductor and of its earth terminal should be
annually tested. As this testing involves some skill and familiarity
with electrical apparatus it would be advantageous if some competent
person were officially appointed, either by the government or by some
recognised authority, to perform this duty.

=INTERNAL MASSES OF METAL.=—All large and long masses of metal, such as
beams, girders, pipes, hot water systems, and large ventilators fixed in
the interior of buildings, should be electrically connected with the
earth, or with the conductor; but the soft metal gas pipes should never
be used as conductors. The inlet and outlet pipes of large meters should
always be, independently of the meter, electrically connected with each
other, for two remarkable cases of the explosion of a meter have
occurred through the presence of a joint in the pipe electrically bad
owing to the use of India-rubber packing. Appendix M, p. (239).

=EXTERNAL MASSES OF METAL.=—Large constructive and decorative ironwork,
such as guttering, flashings, railings, finials, vanes, &c., and all
masses of metals used in building, should be connected to each other,
and to the earth direct, or to the conductor. In fact, the gutters and
water pipes are already frequently utilized as a partially protective
system. The ventilators of soil pipes may also be employed in this way,
and even made sightly by the addition of an ornamental finial fitted
with points, but care must be taken that the joints are metallic and not
made with red lead or putty; and it must not be forgotten that the
conductivity of lead is very small, so that undue reliance must not be
placed upon pipes made of that metal.

SECTION III.—_Code of Rules for the Erection of Lightning Conductors._

The following Code of Rules should be carefully attended to in drawing
out a specification for a Lightning Conductor, the reasons for each
being given in the previous Sections and in the Appendix:—

=Points.=—The point of the upper terminal should not be sharp, not
sharper than a cone of which the height is equal to the radius of
its base. But a foot lower down a copper ring should be screwed
and soldered on to the upper terminal, in which ring should be
fixed three or four sharp copper points, each about 6 in. long. It
is desirable that these points be so platinized, gilded, or nickel
plated as to resist oxidation.

=Upper Terminals.=—The number of conductors or points to be specified
will depend upon the size of the building, the material of which
it is constructed, and the comparative height of the several
parts. No general rule can be given for this; but the architect
must be guided by the directions given at pp. 12 to 14. He must,
however, bear in mind that even ordinary chimney stacks, when
exposed, should be protected by short terminals connected to the
nearest rod, inasmuch as accidents often occur owing to the good
conducting power of the heated air and soot in a chimney (p. 2).

=Insulators.=—The rod is not to be kept from the building by glass or
other insulators, but attached to it by metal fastenings. (See p.
11.)

=Fixing.=—Rods should preferentially be taken down the side of the
building which is most exposed to rain. They should be held
firmly, but the holdfasts should not be driven in so tightly as to
pinch the rod, or prevent the contraction and expansion produced
by changes of temperature.

=Factory Chimneys.=—These should have a copper band round the top, and
stout, sharp, copper points, each about 1 ft. long, at intervals
of two or three feet throughout the circumference, and the rod
should be connected with all bands and metallic masses in or near
the chimney. (See p. 5.) Oxidation of the points must be carefully
guarded against.

=Ornamental Ironwork.=—All vanes, finials, ridge ironwork, &c., should
be connected with the conductor, and it is not absolutely
necessary to use any other point than that afforded by such
ornamental ironwork, provided the connection be perfect and the
mass of ironwork considerable. As, however, there is risk of
derangement through repairs, it is safer to have an independent
upper terminal. (See p. 4.)

=Material for Rod.=—Copper, weighing not less than 6 oz. per foot run,
and the conductivity of which is not less than 90 per cent. of
that of pure copper, either in the form of tape or rope of stout
wires—no individual wire being less than No. 12 B. W. G. Iron may
be used, but should not weigh less than 2¼ lbs. per foot run. (See
pp. 5 to 10.)

=Joints.=—Although electricity of high tension will jump across bad
joints, they diminish the efficacy of the conductor; therefore
every joint, besides being well cleaned, screwed, scarfed, or
rivetted, should be thoroughly soldered. (See p. 10.)

=Protection.=—Copper rods to the height of 10 feet above the ground
should be protected from injury and theft, by being enclosed in an
iron pipe reaching some distance into the ground.

=Painting.=—Iron rods, whether galvanized or not, should be painted;
copper ones may be painted or not according to architectural
requirements.

=Curvature.=—The rod should not be bent abruptly round sharp corners.
In no case should the length of the rod between two points be more
than half as long again as the straight line joining them. Where a
string course or other projecting stone work will admit of it, the
rod may be carried straight through, instead of round the
projection. In such a case the hole should be large enough to
allow the conductor to pass freely, and allow for expansion, &c.

=Extensive Masses of Metal.=—As far as practicable it is desirable
that the conductor be connected to extensive masses of metal, such
as hot-water pipes, &c., both internal and external; but it should
be kept away from all soft metal pipes, and from internal
gas-pipes of every kind, respecting which see page 15. Church
Bells inside well protected spires need not be connected.

=Earth Connection.=—It is essential that the lower extremity of the
conductor be buried in permanently damp soil; hence proximity to
rain-water pipes, and to drains, is desirable. It is a very good
plan to make the conductor bifurcate close below the surface of
the ground, and adopt two of the following methods for securing
the escape of the lightning into the earth. A strip of copper tape
may be led from the bottom of the rod to the nearest gas or water
_main_—not merely to a lead pipe—and be soldered to it; or a tape
may be soldered to a sheet of copper 3 ft. × 3 ft. and 1/16 in.
thick, buried in permanently wet earth, and surrounded by cinders
or coke; or many yards of the tape may be laid in a trench filled
with coke, taking care that the surfaces of copper are, as in the
previous cases, not less than 18 square feet. Where iron is used
for the rod, a galvanized iron plate of similar dimensions should
be employed.

=Inspection.=—Before giving his final certificate, the architect
should have the conductor satisfactorily examined and tested by a
qualified person, as injury to it often occurs up to the latest
period of the works from accidental causes, and often from the
carelessness of workmen. (See p. 14.)

=Collieries.=—Undoubted evidence exists of the explosion of firedamp
in collieries through sparks from atmospheric electricity being
led into the mine by the wire ropes of the shaft and the iron
rails of the galleries. Hence the headgear of all shafts should be
protected by proper lightning conductors.

(Signed)

W. GRYLLS ADAMS.
W. E. AYRTON.
LATIMER CLARK.
E. E. DYMOND.
G. CAREY FOSTER.
D. E. HUGHES.
T. HAYTER LEWIS.
W. H. PREECE.
G. J. SYMONS.
JOHN WHICHCORD.

_December 14th, 1881._

APPENDIX A.

CIRCULAR AND QUESTIONS
ISSUED TO
Manufacturers of Lightning Conductors,
AND
THEIR REPLIES THERETO.

NOTE.—There are only two points requiring mention respecting the
following replies. First, that in order to avoid useless
repetition of the questions, the answers are numbered, and the
corresponding question will be found in the following circular.
Secondly, that the replies are verbatim, as received from the
manufacturers, except that frequent entries will be found in
square brackets, _e.g._ [A 0·11 in.] These represent approximately
the sectional area of the conductors, and are given to facilitate
the comparison of the conducting capacities of the very various
patterns submitted to the Conference.

CIRCULAR.

LIGHTNING ROD CONFERENCE.

30, GREAT GEORGE STREET, WESTMINSTER, S.W.
_November 14th, 1878._

At the invitation of the Meteorological Society delegates have been
nominated by the following Societies:

Royal Institute of British Architects,
Society of Telegraph Engineers,
Physical Society,
Meteorological Society,

to consider the present modes of erecting Lightning conductors, and
improvements therein.

At a largely attended meeting held this day I was instructed to
forward to you the questions stated below, and to request you to
forward with your replies any remarks which you may wish to lay
before the Conference.

If you desire any specimens to accompany your remarks, I shall be
glad if, whenever possible, they do not exceed five inches in
length.

I am,
Your obedient Servant,
G. J. SYMONS,
_Secretary to the Conference_.

QUESTIONS.

(_It is requested that the replies be written on foolscap paper, on one
side only, and that they be numbered in accordance with the questions._)

1. Form, dimensions, and material usually adopted by you for upper
terminals.

2. Material and dimensions of conductor.

3. Is any definite proportion between the length and sectional area of
the conductor observed, and if any, what?

4. Joints, how made.

5. Attachment to building, how made.

6. Ground connection, how formed, and of what extent.

7. Extent of area supposed to be protected.

8. If there is more than one terminal, is the size of the conductor
increased?

REPLIES.

39, WAPPING, LONDON, E.

1. The upper terminals are made of a copper tube ⅝ inches in diameter
and 1/16 inches thick [A. 0·11 in.] In the upper end of the tube is
fitted 15 inches of copper rod tapered to a point at the top, into which
is fixed 3 or more smaller rods about ¼ inch in diameter [A. 0·05 in.]
each tapered to a point, and brought into the parent rod in a curve (not
at an angle). The next part of the tube, down to about 9 inches from the
bottom, is filled with a stiff iron rod to strengthen it, the lower end
of the tube being left open to receive the rope. This constitutes what
is called “the point.” These points vary in length from 2 or 3 to 8 or
10 feet when used for buildings. A square-topped tower would require a
much higher point than would be necessary for the top of a spire.

Sometimes the points are tipped with platinum, which we consider to be
altogether superfluous.

2. The conductor is simply a wire rope, varying in size, and mostly
either ⅜, ½, or ⅝ inches in diameter [A. 0·11, 0·20, or 0·31 in.] These
ropes are made in two different forms: the one ⅜ inch diameter [A. 0·11
in.], most suitable for ships’ use, is composed of 49 No. 18 guage
copper wires, each wire having a circumferencial measurement of ·157
inches [A. 0·002 in.]; the circumferencial or surface measurement of the
whole of the 49 wires is equal to 5·693 inches [A. 0·11 in.], or say,
equal to the surface of a copper band 2·846 inches wide—_i.e._,
measuring both sides of the band.

The other make, say ½ inch diameter [A. 0·20 in.], much used for lofty
buildings, is composed of 7 No. 7 guage copper wires, each wire having a
circumferencial measurement of ·581 inches [A. 0·027 in.]; the
circumferencial or surface measurement of the 7 wires is equal to 4·067
inches [A. 0·19 in.], or say equal to the surface of a copper band 2·033
inches wide.

3. There is no definite proportion observed between the length and
sectional area of the conductor. We take it that the sectional area
should be the same, irrespective of length, as we do not trace that
lightning varies in intensity while passing through a conductor of
greater or less length. The rather prevalent idea that a smaller
conductor is sufficient for a low building is, we think, erroneous, as
we do not find any data to show that lightning in its descent loses any
portion of its force until it actually enters the earth.

4. The copper rope is joined to the upper terminal by passing the end of
the rope into the tube at the lower end of the terminal for the space of
about 9 inches, and fixing it with 3 copper rivets. There is no other
join in the conductor whatever—a feature of much greater importance than
is sometimes admitted.

5. The upper terminal is passed through two strong earthenware
insulators which are usually fixed to the building by two strong
galvanized iron staples. Other modes of fixing the terminal must
sometimes be resorted to, as some factory chimneys are capped with iron,
and buildings of varied forms must be treated with according to
circumstances. Having fixed the terminal, the rope may then be led down
the building on the most convenient side for the purpose, and fixed at
intervals of 6 or 8 ft., according to circumstances, with glass
insulators supported by copper brackets. The rope should be given the
straightest course practicable from the upper point down to the earth,
carefully avoiding all angles, specially an acute angle, as much as
possible, and in its passage it should be kept clear from any other
metal in the building.

There are three matters to which we would call special attention, viz.:

_Insulators, Angles and Joints, Metal in Building._

_Insulators._—When copper rope lightning conductors were first
introduced, about the year 1837, a circumstance occurred which at once
proved the efficiency of the conductor, and suggested the use of
insulators. The late Mr. Andrew Smith, C.E., had fitted a factory
chimney in the East of London with a rope conductor, which was fixed to
the chimney by iron staples. In a violent storm which occurred soon
afterwards, the lightning was seen to pass down the conductor, which
remained unaltered in any way; but on examining the chimney it was found
that the brickwork had received a concussion at most, if not all, of the
staples, showing that the lightning in passing had expended part of its
force on the iron staples. It is probable that, if the staples had been
made of thicker iron, and had been so placed as to lead off from the
conductor with easy curves inwards, instead of being driven into the
wall at right angles with the conductor, the concussions would have been
much more violent than was the case.

_Angles and Joints._—It must be obvious to any one that lightning, as
well as any other matter or thing which travels at high speed, would be
greatly obstructed in having to turn corners. It must also be borne in
mind that lightning is of intense heat, and while passing in a straight
line the effect of its heat is lost in the velocity of its motion; but
in passing an angle its momentary pause (much too brief to be
calculated) is sometimes enough to create sufficient heat to fuse the
conductor at the angle. For this reason all angles must be avoided, and
easy curves having a downward tendency substituted.

The angles in copper tube conductors are doubly objectionable, for,
having joins as well as angles, they are liable, by the effect of heat,
to become disjointed. It would be difficult, if not impossible, to fit a
tubular conductor, except in a straight line from end to end, without
this double objection. Similar objections apply also, in a greater or
less extent, to the copper band conductors, as they are made with joins,
and, when fixed up, are usually carried into and over as many angles as
come in their way. They do not so readily follow all the sinuosities of
a building as a rope does on the curve principle.

The flat band conductors, which are composed of a number of galvanized
iron and copper wires combined, are simply a frivolity.

_Metal in Buildings._—Taking the conductivity of copper as from 7 to 10
times greater than that of iron, it would probably follow, that if two
rods, the one of copper the other of iron, in these proportionate sizes,
were brought together in one common terminal or point, and led by the
same course to the earth, as much of the fluid would possibly pass down
the one as the other. On this principle, we avoid contiguity with any
metal in a building, especially if in large masses, such as machinery,
&c.

_Ships’ Conductors._—In fitting the rope conductor to a ship’s rigging
it is only necessary to pass it through a hole in the truck, so that the
end may stand about 6 inches above the truck. It may be held up by a pin
or key passed through the rope close over the truck, and then carried
down the topgallant backstay (to which it should be tied at intervals
with yarn) to the gunwale, where a sufficient length of the conductor
should be kept in a coil to reach well down into the sea in any position
of the ship. In stormy weather the coil may be untied, and by its own
weight the end will drop down into the sea as required. Sometimes the
rope is shackled at the gunwale to a strip of sheet copper about 3
inches wide, which is nailed down the ship’s side till it meets the
sheathing at the bottom. The strip of copper should _overlay_ the
sheathing for a few inches. It may be noticed that this kind of
conductor, fitted with a coil at the gunwale, is without any join
whatever, and that it takes almost a straight course direct from the
truck into the water.

The copper band conductors let into the mast and carried through the
hull of the ship are objectionable and unsafe, as, in passing from each
portion of the mast, they require moveable joints, so as to admit the
several parts of the mast being run up or down as required. These joints
present angular interruptions which may become out of order, and, in
passing through the hull, any rupture of the band in that part, or the
contiguity of other metals, may cause serious consequences. Certainly,
there can be no necessity for carrying the lightning through the ship
when, by a safer and much more simple method, it may be kept altogether
outside.

In the smaller vessels, where the mainmast is well above the other
masts, it may be sufficient for that mast only to be fitted with a
conductor, but in larger ships, particularly long steam-ships, where the
masts are a considerable distance apart, each mast should have a
conductor.

We do not, either in theory or in practice, know any necessity for
protecting the yards with conductors, though it is not altogether
improbable that, in the absence of conductors on the masts, the yards
might get damaged while the masts remain uninjured.

6. The end of the rope should be buried in moist earth, and carried in a
curve to 5 or 6 feet from the foundation. In clay ground and on the
shady side of a building about 3 feet below the surface would be deep
enough; but in lighter ground, and particularly on the sunny side, it
should be buried 6 or 7 feet deep, to ensure sufficient moisture at all
times of the year.

7. As the course by which lightning approaches the earth is very
devious, it would be difficult to determine with certainty the extent of
area protected; but, viewing the absence of damage to the most remote
parts of the roofs of buildings which have been properly fitted with
conductors within the last 40 years, we should think the area protected
may be taken as equal to from 3 to 5 or 6 times the height of the
conductor.

8. When two or more terminals are used, the main rope should be somewhat
enlarged; otherwise, the collective quantity of fluid received on the
several points may be too great for the common channel.

WILKINS & WEATHERBY.

* * * * *

DORA STREET, LIMEHOUSE, E.

We have to own receipt of your valued communication of the 14th ult.,
and with great pleasure to submit for the consideration of the
Conference the following replies to their questions. We have endeavoured
to make them as explicit as possible, but it is difficult adequately to
describe our system on paper, and we suggest for the consideration of
the Conference the advisability of showing any Committee they may
appoint one or two of the numerous public buildings fitted by us.

Any further particulars or drawings you may require we shall be glad to
send you; and it is with great pleasure that we add that any services we
can render you in your valuable investigations are at your disposal.

1. A five-pointed copper spindle, the sharp points of which are
silvered, and single points on high chimney shafts to the number of four
or five.

2. Copper solid bands, or tubes, “as samples sent,” being simple,
durable, cheap, and the most capacious form for the safe conduction of a
heavy stroke of lightning, the bands being from 1 inch to 3 inches in
width and ⅛ inch thick [A. 0·12 to 0·37 in.], and the tubes from ¾ to 1½
inches in diameter and ⅛ inch thick [A. 0·24 to 0·54 in.].

3. Yes; experience has proved that nothing less than 1½ inch bands [A.
0·18 in.] should be used for the main conductor to ordinary houses, with
¾ [A. 0·09 in.] to 1 inch [A. 0·12 in.] bands for branches, and from 2
to 3 inches [A. 0·24 to 0·37 in.] bands as main conductor to buildings
of large area, with 1 to 1½ inch [A. 0·12 to 0·18 in.] for branches; or,
in the case of chimney shafts, ¾ inch to 1½ inch tube [A. 0·24 to O·54
in.] for main conductor, and 2 to 3 inches flat band [A. 0·24 to 0·37
in.] for tops of same.

4. The bands are in long lengths, are lapped, closely rivetted and
soldered, to form a continuous band; while the tubes have patent
insertion joints, the upper end being turned and fitted into the lower
end, which is bored, and the tube then forms a continuous line
externally and internally.

5. Copper holdfasts to suit shape and size of conductor.

6. Not less than 30 feet of 1½ inch to 2 inch copper bands [A. O·18 to
0·24 in.] in two or three branches, with forks at end of each band, and,
if water is not near, the trenches half filled with carbonaceous
materials and well watered, as this material will readily absorb the
least moisture and retain it, while being in itself the best conductor.
But much will depend upon the nature of the ground; for if chalk or rock
foundation and water cannot be got at, the ground branches must be at
least doubled, and the trenches deeper and made up of carbonaceous
materials and earth.

7. Our experience is that no appreciable extent is protected by a single
rod conductor in the presence of other influences. The chimney-stacks,
lined with carbon in the shape of soot, with the heated gases, cause a
rarefaction in the atmosphere, and form an easier passage for the
electric fluid. Roofs and buildings having large masses of metals will
be more likely to influence lightning than the single line of copper rod
generally fitted. Many cases have occurred of chimney-stacks 4 feet to 9
feet across being struck opposite the conductor, and lead roofs,
gutters, lead ridges, &c., from 10 feet to 20 feet from the rod
conductor.

8. No; the system of conduction used by us does away with this, the
lines of conduction being ample.

REMARKS.

From our close connection with the late Sir William Snow Harris, adviser
to the Crown for upwards of twenty-five years in regard to lightning
conductors for the navy, and having made lightning conductors our
especial practical study for thirty-five years, we may be pardoned for
making a few remarks on the protection of buildings from lightning.

We would, firstly, say that the system of conductors now fitted by us is
based upon these past years of experience, and upon facts collected
during this period, of accidents to buildings having the ordinary single
line of conduction, as also from the practical success of the conductors
in the navy.

The form of conductors used by us has been adopted after considerable
experience, as being the most simple, solid, durable, and capacious form
of conductor for the safe conduction of heavy strokes of lightning.

In place of insulators as fastenings, we use copper holdfasts, as we
found the former dangerous and useless, as the glass, being
non-conductive, the expansion and heat of the electric fluid, being
confined, broke them, and caused an unsafe concussion; and it is also a
disadvantage for a conductor to be away from the building, as nearly
every material in nature assists, without detracting from, the safe
discharge of the electric fluid through a good copper conductor. We find
that the copper wire rope conductor, usually applied, is seldom more
than ⅜th of an inch in diameter; but we did once remove, from the tower
of St. Mary’s Church, Taunton, a copper wire rope conductor of ⅞th of an
inch in diameter [A. 0·60 in.], said to be especially made to
order—certainly the largest we ever came across; but it failed to give
the necessary protection in a lightning storm, which did much damage to
the tower and roof of the church. As capacity or weight of copper is the
most important for safe conduction, copper wire rope is very deceptive
in this respect, as will be seen by the following comparisons, viz.:—A
copper wire rope conductor of ⅜ inch diameter [A. 0·11 in.] weighs 2¾
ounces per foot, not equal to a plain solid band ⅜ inch wide and ⅛ inch
thick [A. 0·046 in.], which weighs 2·907 ounces per foot. A copper wire
rope conductor of ½ inch diameter [A. 0·20 in.] weighs 5 ounces per
foot, not equal to a solid band of ¾ inch wide and ⅛ inch thick [A.
0·092 in.], which weighs 5·814 ounces per foot. A copper wire rope
conductor of ⅝ inch [A. 0·31 in.] weighs 9½ ounces per foot, not equal
to a solid band of 1¼ inch and ⅛ inch thick [A. 0·153 in.], which weighs
9·690 ounces per foot. This is the largest size of wire rope conductor
made or used.

From the above will be seen what protection can be given by conductors
of such small capacities; and we may add that solid band conductors of
the same weight, and superior in every way, can be fixed at less than
half the cost of the wire rope, _foot_ for _foot_.

Copper chains and copper wire bands, as conductors, answer in so
uncertain a manner with the galvanometer, that they should never be
used.

Iron in any form should be avoided, from its lower conducting power, and
its utter uselessness when in a rusty and decayed state.

With regard to testing with the galvanometer, the mere testing of the
conductors is no proof of the security of the building itself. We not
only test the conductors, but also the building, to prove that it is
under safe conduction in lightning storms.

In conclusion, we beg to state that our patent system of protection is
the application of one or more main down and ground copper conductors
and sizes, according to the height and area of the building, the fitting
of the copper bands to each chimney-stack, and connecting the same, and
the connecting of all the metals on the roofs thereto and to the main
conductor, so that there shall be no circuit by which the lightning
fluid would be likely to attack without having its exit to the main
conductor.

For high working chimney-shafts we fit a copper band round the top, and
four points thereon connected to main down conductor.

For further information, we earnestly solicit the careful perusal of our
pamphlet and papers herewith.

J. W. GRAY & SON.

* * * * *

CHIPPENDALE MEWS, HARROW ROAD.

1. Upper terminals pointed with one or more points, according to the
nature of the building to be protected. Dimensions vary in like manner.
Material—copper or brass, with electro-gilded points.

2. Conductor composed of copper or galvanized rope, according to height,
&c., of building, &c., dimensions varying with resistance of the
circuit.

3. The sectional area varies with the length.

4. Joints made, as far as possible metallically; where solder cannot be
used, screw joints are made use of.

5. Attachment to building direct by metallic ties of requisite form.

6. Ground connection—When practicable, the end of conductor is
metallically connected with gas or water _main_, otherwise a hole is dug
deep enough to meet always moist earth. The end of conductor is either
attached to an earth plate, or coiled up in a bundle and surrounded by
coke.

7. The area protected is supposed to be a radius equal to the height of
conductor.

8. If more than one terminal is attached to one conductor, the size of
the latter is increased, except under certain conditions.

F. RUSSELL & CO.

* * * * *

137, PRINCESS STREET, MANCHESTER.

1. A copper tube 1¼ inch diameter or 1 inch diameter, finished at the
upper end, with a forged copper point or cone, connected with the tube
by a cast copper (or gun-metal) coupling, into which coupling are also
screwed three or more smaller points round the larger central one. At
the lower end the tube is screwed into a somewhat similar coupling, to
receive also the brazed and screwed end of the conductor. Or a solid
copper rod ½ inch diameter [A. 0·20 in.], or _wrought_ iron rod 1 inch
diameter [A. 0·79 in.] (where iron conductors are used) the rod in
either case forged to a blunt point, and screwed at the lower end, like
the tube first described, to fit the coupling.

2. (_a_). Copper wire rope of 7 strands each, No. 10 Birmingham wire
gauge, or in specified cases of No. 8 or 7 wire gauge, making, when
spun, a rope with a sectional area varying from 7/16 to 11/16.

(_b_). Solid copper rods ½ inch diameter [A. 0·20 in.].

Solid iron rods 1 inch diameter [A. 0·79 in.].

(_c_). Copper band or “tape” of sizes from ¾ × ⅛ to 2 or 3 × 3/16
inches [A. 0·09 to 0·38 or 0·56 in.].

(_d_). Copper tube ⅝ inch diameter outside, and ⅛ inch thick [A. 0·20
in.]

3. Although no definite rule exists for the proportional sizes of the
conductor, it is usual and prudent in a large building to employ for the
main conductors, which should come from the highest and most exposed
points to the earth in the most direct way, a larger conductor than
would be required for a small building, and the branches or connections
to this main conductor may be smaller in sectional area than the
principal one. Thus, a church tower with four angle pinnacles may be
protected by four finials or points, one to each pinnacle, and these
four parts fitted to rope of 7 wires No. 10 gauge [A. 0·10 in.], to be
united to a continuous band round the parapet, from whence a rope of 7
wires No. 8 gauge [A. 0·15 in.] should descend into the earth; or an
infirmary or workhouse built with wings would have, perhaps, three
direct rod conductors, one to each chimney stack, and connections with
the water spouts, or lead flashing made of small copper tape ¾ × ⅛ [A.
0·09 in.] _soldered_ to the lead and worked round the rods.

4. The fewer joints the safer, and for this reason—the copper _rope_ or
_tape_ is better than the rod or tube, as the former is made
conveniently any required length, and the danger of a fault or break in
the continuity is avoided. Of the necessary joints the rope requires one
at its junction with the top rod or tube; this is made by brazing a
small ring of brass (or copper) round the rope; the solid end thus
formed being chased with a deep male thread, which fits the prepared
base of the rod. The branch conductors or connections, with adjacent
constructive or decorative iron work—as beams, girders; cresting, vanes,
&c., are made by threading a bead with a similar ring to receive the
branch, as that already described. Where the branch reaches its object a
ring or solid coupling should be “tapped” into the girder or cresting,
to ensure thorough metallic connection, if the destination of the branch
be the lead flashing, the seven wires must be opened like a fan, and
_each wire_ strongly soldered with common plumbers’ solder to the lead—

(_b_). Copper or iron rods are made continuous by couplings of either
metal, as the case may be, which should exceed the diameter of
the rods by enough metal to allow of a good thread. These
couplings should be hexagonal or octagonal in plan, to allow the
workman a certain grip; and the thread should be of the kind
called right and left, so that while screwing one length he may
not unscrew the other. These conductors require very careful,
steady workmen, as a great element of danger exists in these
numerous joints.

5. The various natures of the buildings provided with conductors require
separate, and often different treatment: but the principle in all cases
is the same, viz., to attach the conductor closely to the fabric, and
the more the conductor is made an integral part, as it were, the more
efficacious it will be. Any attempts at so called isolation are opposed
to the theory of protection by conductors. The mechanical means of
fixing are best illustrated by diagrams, the chief objects to be
considered are—

(_e_). Permanence or strength and durability.

(_f_). Room for expansion of the conductor.

(_g_). Facility in fixing without cutting or breaking the conductor.

(_h_). Neatness in appearance.

These objects are gained by a careful consideration of the materials to
which the conductors are fixed by “holdfasts,” for stone, slate or
tiles, wood, and iron. It is important that _sharp_ bends be avoided. A
string course, for instance, should be drilled, and the rod or rope
passed straight through. Also, that any metal bodies in the line of the
conductor should be connected with it by staples screwed into such
bodies. It is most necessary that the ends of vane bolts or rods should
be joined to the conductor, or, where this is impossible, should be
fitted with an independent wire or rod to the earth.

6. The connection with the ground is of special importance, as the
object of the conductor is to provide a free passage between the two
currents, and if this be not done, a lateral discharge is pretty sure to
result. A building provided with suitable conductors, properly fixed,
should at all conditions of the atmosphere, allow a free course to the
electricity, and be in all its parts electrically equivalent, and with
this intention the several parts (as mentioned in answer to question 3)
are brought into connection with each other or with the ground. The
actual length of the ground conductor is fixed by the nature of the
subsoil, as it is obvious that dry sandy soil is unsuitable for a
termination. We therefore continue the rope or tape until a good damp
earth is reached, if possible, a spring or open water—generally
speaking, about 5 to 10 yards will be sufficient in most localities. The
conductor is then buried 5 to 10 feet, or upwards, in the damp earth or
water. If a rope, the several strands are unravelled and opened out: if
a rod or tape, a discharging fork is usually attached to the end to
promote the easy discharge, for which purpose it is also usual to fill
the trench with charcoal. The trench must be dug with a slight fall from
the building downward.

7. The extent of area supposed to be protected by the conductor is
estimated by many as included in a radius of double the height of the
conductor from the base line; but the immunity from accident enjoyed by
many buildings situated at a greater distance from a number of tall
factory chimneys; or to take an opposite example, in a city where there
are many lofty spires or towers, would go to show that a number of
conductors attached to tail objects, serve to obviate the dangers
arising from lightning by providing, at many different points, a direct
communication between the positive and negative currents which exist in
the clouds and earth. We have never known a church spire, when the
conductor was fixed in accordance with ordinary skill, injured by
lightning; and the tall factory chimneys of our manufacturing towns
afford strong corroborative evidence of the value of conductors, and
this in two ways—first, because those to which conductors are fixed, do
not get struck; and, second, because those unprovided with conductors,
_do_ get destroyed from time to time.

8. A reference to the answer to No. 3 question, will show that we
consider that when several terminals are used, an increased diameter is
advisable in the main or principal conductor; but it must be remembered
that either of the conductors referred to in the answer to question 2,
is greatly in excess of what many eminent electricians consider
necessary. A single wire being thought sufficient of 3/32 inch diameter
(A. 0·06 in.) for any ordinary current of electricity. But both the
English and French Governments have thought it prudent to specify a
copper body, with a sectional area of ½ inch in English, or 1 centimetre
in French (0·40 in.)—partly to provide against corrosion, which would
rapidly deteriorate a thin wire, and partly to obviate the danger of the
melting of the smaller conductor under the continued force of an
unusually strong shock of lightning. We, therefore, respectfully follow
the decision of such experts as have, by careful experiment and
considerable diligence, acquired the knowledge they possess—both as to
the substance, the form, and the treatment of this subject; and have
only to add the fact, that any small experience we have practically had,
goes to support the conclusions already arrived at by these authorities.

FREEMAN & COLLIER.

* * * * *

24 & 26, LEVER STREET, MANCHESTER.

1. Our upper terminals are made of copper or brass, plain spike or ball
with spike at top, and three radiating from it, or four or five spikes
radiating from the ball. Attached to the ball (screwed into it) is a
solid rod of copper, to which the conductor is fastened, as explained
below.

2. Conductor is made of good quality copper wire strand 7 ply: ⅜ inch
[A. 0·11 in.] to 7/16 inch [A. 0·15 in.] diameter.

4. Joints of the strand not usually permitted, as we spin it any
reasonable length.

The end of the conductor is knotted and drawn through a cup-shaped ring
of metal one end, the top of which is screwed into the bottom of the
solid rod of the terminal. This makes a good connection.

5. Copper holdfasts fasten the rod to the building.

6. Ground end is coiled loosely in damp earth or a well.

RICHARD JOHNSON, CLAPHAM, & MORRIS.

* * * * *

180, ROTTEMORE, GLASGOW.

We beg to reply to your queries on the material, system, and fitting of
lightning conductors, as practiced by us for over 25 years, during which
time we have never had a building injured in which we have been engaged,
and have fitted from 15,000 to 20,000 feet a year, without
advertisement.

1. Uniformly solid copper, consisting of 1 centre concave point, about
14 inches long, presenting 8 sharp angles = 3½ inch surface; this is
surrounded by 4 smaller points of same construction. These all terminate
or spring out of a hollow copper ball, which is screwed on a copper tube
¾ inch diameter inside, and from 4 inches to 5 inches long, according to
requirement. The copper cable is passed through this tube, is knotted
inside of the ball, and the points are all screwed against it, which
forms the point of contact, and thoroughly fixes the cable at the top;
but the fixing of the top or terminal rod is fashioned in accordance
with the requirements of the building or material to be fixed to.

2. Uniformly copper cable constructed of 49 strands, _hard drawn square_
copper wire Nos. 17, 18, or 19 w.g.

3. We never use less than 6–inch surface, _i.e._, measuring the
circumference of each wire, we contending that surface is the only power
of the conductor. Up to 150 ft. we use No. 19 (= ½ inch diam.) [A. 0·20
in.], ¾ inch for a longer length of cable (_i.e._, 17 or 18) [A. 0·44
in.].

4. Usually with a gun-metal screwed coupler.

5. With brass holdfasts, lined with porcelain, glass, or guttapercha.

6. Spread out end of strands of cable like a fan, and bury it in the
moist earth a few feet deep, in an oblique way tending from building.

7. 30 to 40 yards.

8. We invariably run one cable from each terminal or top rod: but in
spires we commonly take a connection from the _bottom_ of the vane rod,
and connect it to the main conductor, which goes to the highest point of
vane or final: if the former, we fix a copper bush or disc to the vane
rod at foot of vane, which is fast to cable, and a corresponding one on
vane, with cable at highest point, when the cable is fringed out,
presenting its 49 points, and by these discs the vane revolves with that
portion of the conductor attached, and the point of contact is given by
the discs.

C. H. PENNYCOOK & CO.

* * * * *

ALL SAINTS’ WORKS, DERBY.

1. Form for upper terminals:—A straight copper tube, ¾ inch diameter;
thickness of metal, 15 B.W.G. [A. 0·15 in.], with solid copper point (no
branches); the point is soldered and rivetted into the tube; or a solid
copper rod, ½ inch diameter [A. 0·20 in.], tapering towards the top.

2. Material and dimensions of conductor:—Either a copper band of 2½
inches wide and No. 16 B.W.G. thickness [A. 0·16 in.]; or a copper wire
rope, ½ inch diameter, of 6 strands, each strand containing 6 wires [A.
0·20 in.].

3. Proportion between length and sectional area of conductor:—The ½ inch
copper rope [A. 0·20 in.], or 2½ × 16 B.W.G. band [A. 0·16 in.], is used
for heights not over 120 feet; for higher buildings, a ¾ inch rope [A.
0·44 in.] or band, 2½ × 12 B.W.G. [A. 0·27 in.] should be used.

4. Joint, how made:—Joint is made between band and copper rod with a
brass screwed socket, the rod is soldered and rivetted into socket, and
the band is soldered round socket, then soldered and rivetted. When the
copper rope is used, a hole is drilled into socket, same diameter as
rope, at the lower end, and turned out conical shape; the rope is then
passed through the socket, the ends spread out, and the spaces filled up
with solder.

5. Attachment to building:—The conductor is fixed close to building
_without_ insulators, and is brought into close contact with the
spouting; is closely attached to chimney and walls by means of copper
straps and copper nails driven into the masonry.

6. Ground connection:—Should a good, permanent drain be near, the
conductor is brought to it and bound round and firmly fixed.

If there should be an open drain or brook, the conductor is brought
under it at _sufficient_ depth that if the stream be dry at any time
there will be sufficient moisture to carry away the charge without
disruption. Should there be neither drain pipes nor brook sufficiently
near, the conductor is taken from 12 to 20 feet below the surface to the
clay, where it is certain to be always damp, even in seasons of the
greatest drought ever known.

In no case should the earth connection be taken into a closed tank or
well.

If a band be used, it should be cut into strips about 18 inches long and
laid in different directions; rope should be unwrapped and spread in a
similar manner.

7. Supposed area protected:—It is impossible to determine exactly the
area the conductor protects. It is erroneously supposed that the rod
will protect buildings within its radius, but experience will not bear
out this axiom. Many instances may be related of buildings being struck
much within the radius of well-protected churches or chimneys.

The protection a conductor affords depends to a great extent on the
relative positions of the electric discharge and the objects that it may
meet in its course. As a general rule, a church with a high spire with a
proper conductor may be considered to protect the remainder of the
edifice; but a low, straggling building should have several conductors
at the _outside_ highest points.

8. If there is more than one terminal is the size of conductor
increased?—No; as sufficient material should always be used to carry off
without disruption the heaviest known charge, it is unnecessary to
increase the size of conductor. Should two or more upper terminals be
connected with the main conductor, the size of material need not be
increased; for if two or more terminals receive the charge
simultaneously it necessarily follows that it is sub-divided; therefore
the conductor will have no more work than if one point only had been
struck.

_Note._—We quite agree with Snow Harris regarding insulators, that if
there be anything in insulators they are a disadvantage, for if the
building be struck in any other part than the conductor, the current
cannot easily find its way to the conductor. The current will take the
line of least resistance; therefore it is reasonable to assume that the
building is more certain to escape the disruptive force of lighting when
the conductor is in close proximity with the building.

JOHN DAVIS & SON.

* * * * *

BIGG MARKET, NEWCASTLE-ON-TYNE.

1. For upper terminals I generally use ½ inch diameter solid copper rod
[A. 0·20 in.], or ¾ inch diameter tube [A. 0·24] with four points, and I
fix them 4 or 6 feet above the building they are intended to protect. I
always endeavour to get the upper terminal as near the size of the
conductor as is consistent with strength. I make my points of the best
copper tipped with platinum.

2. For the conductor I use ½ inch diameter copper wire rope [A. 0·20
in.], which is (in my opinion) the best and most applicable conductor
used, as it appears to be an open question, at present, whether it is
surface or mass which conducts. If it is mass, then a tube conductor is
insufficient. If it is surface, then a solid rod is superfluous. The
copper tape conductor I consider the worst form of any, as it bends too
easily round sharp corners, projections, &c., of buildings, which is a
thing to be avoided as much as possible. A conductor should be brought
to earth as direct as possible, and with no bends if they can be
avoided. The copper wire rope conductor has both surface and mass
conduction, and can be led about roofs and other difficult places better
than any other form of conductor that I know of.

3. None; I imagine it is not necessary.

4. I avoid joints as much as possible; but, when they must be made, I
scrape the ends of my wire bright, and then splice or interlace them
together, covering the whole with thin sheet lead—I object to solder, as
I think it must interfere with surface conduction; the wire is fastened
to the upper terminal, with a Matthew Walker knot let into a hollow cup,
and the terminal screwed down on it.

5. I attach my wire to the building with a brass or gun-metal holdfast 4
inches long, having a ⅝ hole, the inner edge being flush with the wall
of the building, so as to allow the conductor to touch the wall of the
building all the way up, and still allow plenty of room for the free
passage of the electric fluid. I do not approve of insulators, nor yet
of that kind of holdfast that is driven in tight on to the wire, for I
think that must interfere with the clear passage of the electric fluid.

6. I cut a trench some 15 or 20 feet long, gradually deepening from 1
foot at the commencement to 4 ft. at the termination, which I fill with
pounded charcoal and bury the wire in it. Earth-plates are not necessary
when this is done.

7. It is calculated that a conductor will protect a surface in the shape
of a cone, the diameter of the base of which is equal to the height of
the conductor. Thus, if a conductor were 100 feet high, the space
protected would be represented by a straight line drawn from a radius of
50 feet from the base of conductor, to a radius of 8 or 10 feet from its
highest point.

8. I consider, if there are two terminals, there should also be two
wires, or the wire should be of sufficient capacity to carry off a
double charge, in case both terminals should be struck at one time. I
think the conductors should certainly be of sufficient capacity to carry
off any charge that might be received by the terminals, be they few or
many.

T. MASSINGHAM.

APPENDIX B.

ANALYSIS OF, AND REMARKS UPON,
THE VIEWS OF MANUFACTURERS.

On Nov. 14th, 1878, a circular was issued to the principal lightning-rod
manufacturers in this country, inviting their replies to various
questions that were submitted to them, and also any remarks that they
might wish to lay before the Conference.

Replies have been received from—

Messrs. WILKINS & WEATHERBY, of London.
Messrs. GRAY & SON, of London.
Messrs. F. RUSSELL & CO., of London.
Messrs. JOHNSON, CLAPHAM, & MORRIS, of Manchester.
Messrs. FREEMAN & COLLIER, of Manchester.
Messrs. PENNYCOOK & CO., of Glasgow.
Messrs. DAVIS & SON, of Derby.
Messrs. MASSINGHAM, of Newcastle-on-Tyne.

All well-known firms, who have written fully and freely, and whose
experience is very extensive.

It is impossible to read these replies without feeling the absolute need
of such a Conference as that which has been formed, to collect facts, to
digest opinions, and to endeavour to formulate some guiding principles
for uniformity in practice—for here we have the most diverse modes of
execution detailed, the most opposite views expressed, and the most
varied experience narrated. In fact, some ideas enunciated are quite
opposed to the teachings of science. Where practice is so opposite,
error must abound: and, therefore, there must be great need for an
effort to reduce the system of constructing lightning conductors in this
country to some uniform basis. On no one single point, except in the use
of copper and the necessity for reaching damp earth, do any two
manufacturers agree in adopting similar measures.

I will take each question submitted _seriatim_.

1. _Form, dimensions, and material usually adopted for upper terminals._

There are single points and branching points, fine points and blunt
points, cones, spikes, balls with spikes on top, and balls with
radiating spikes.

The dimensions vary with each form, and they are made of solid copper
and copper tube, of brass, of iron, and of gun-metal. The ends are
sometimes silvered, sometimes gilt, and sometimes tipped with platinum.
But there is no rule or uniformity; and one manufacturer acknowledges
that, while he sometimes tips the points with platinum, he considers the
practice to be altogether superfluous.

Now it is clear that if there be any electrical efficacy in points _as
points_, they should be made in such a form, and of such a material, as
to maintain their efficiency permanently. The writer is very strongly of
opinion that the efficiency of lightning conductors is due principally
to the peculiar electrical action of their points. He sees no advantage
whatever in multiplying these points. In his opinion each conductor
should end in one fine platinum point. It would thus act as a dissipator
of the electric charge in its immediate neighbourhood, and would then
_prevent_, and not favour discharge. Moreover, points demand frequent
inspection, attention, and renewal. He thinks that one function of the
Conference should be to examine some of these points _in situ_, if
possible. At present they are erected and left to their fate.

2. _The Material and Dimensions of the Conductor._

The use of copper is almost universal, but two manufacturers
occasionally use iron. The form varies. The majority use wire rope, but
some use rods, others bands or tapes, others tubes. One firm uses a
cable “constructed of 49 strands of hard-drawn _square_ copper wire.”
Another firm uses a wire rope, simply because “it appears to be an open
question, at present, whether it is surface or mass which conducts.” The
dimensions are as varied as the form, from a wire rope ⅜th of an inch in
diameter to a copper band 3 inches wide and ⅛th thick.

The only point worthy of note is, that no one uses a smaller conductor
than a copper rope ⅜th in diameter (_i.e._ 4 oz. of copper per foot
run).

Leaving the dimensions as a question for future investigation, the
points submitted for the consideration of the Conference under this head
are—

1. Is conduction a question of surface or of mass?

2. Is copper alone to be used?

3. Is the conductor to be in the form of a rope, a rod, a tube, or a
band?

Now, on the first point the writer entertains no doubt whatever that the
conduction of atmospheric electricity is simply a question of mass, and
that the lightning protector acts simply as a conductor obeying the laws
of Ohm.

On the second point he sees no objection whatever to the use of iron,
when properly galvanized, in situations free from chemical impurities.
The reasons urged against its adoption are extremely weak. First, it is
said to decay rapidly; and, secondly, it is said to be a very much worse
conductor than copper.

The rusting of iron is almost entirely checked, in pure air, by
galvanising or coating with zinc. It is used for nearly every other
purpose in connection with building, and it is difficult to understand
why it should be discarded on account of its liability to decay for this
particular purpose, where it is always under supervision.

Again, pure copper conducts about six times better than pure iron: but
we never get pure copper in lightning conductors. Moreover, the
manufacture of iron wire for telegraphic purposes has increased so
enormously during the last two or three years, that the wire now
supplied conducts 50 per cent. better than it used to. Hence the
difference between the two in this respect is not so great as theory
indicates; and it would be well for the Conference to satisfy itself on
this point by having similar sized wires made of the two materials, and
having them measured electrically for their resistance.

But it has been pointed out by the late Mr. Brough (_Phil. Mag._, May,
1879), that by regarding (1) the influence of the rise of temperature,
(2) the difference between the specific heats, and (3) the relative
dimensions, iron conductors can be made much smaller than was formerly
supposed: and, that as iron is so much cheaper, iron rods can be made
equally efficient for a much less sum than copper. Moreover, the use of
iron enables the architect to use one kind of metal throughout his
structure, and thus avoid anywhere the contact of dissimilar metals,
which always results in decay.

On the third point, the writer is clearly of opinion that a galvanized
iron _rope_ is amply sufficient for country residences and buildings
free from chemical actions. In such places, and in towns, copper should
be used. A rope, whether of iron or copper, is easily handled, it can be
made of any size, it can be led in any direction without bends or
angles, it is neat and easily jointed, diverted, or lengthened.

The writer refrains from expressing any opinion on its dimensions here,
for this is a point that will require most careful examination by the
Conference.

3. _Is there any definite proportion between the length and sectional
area of the conductor?_

The majority of the manufacturers increase the size of the conductors
for high buildings—one making the limit 120 feet, another 150 feet,
while a third “varies the sectional area with the length.” One firm does
not consider any difference necessary, while another takes it that the
sectional area should be the same irrespective of length, for “lightning
does not vary in intensity while passing through a conductor of greater
or less length.”

Now, the laws of electricity clearly show that to maintain equal
efficiency we must vary the sectional area as we increase the length of
the conductor; but it is a question for the Conference to decide whether
we should not recommend a rope of uniform dimensions that would be
equally applicable for high and low buildings. Within ordinary limits
the necessity for increased thickness for increased height is scarcely
evident, but the remedy of an increased sectional area, with the number
of separate points erected, is very clear. Indeed, each point should be
the terminal of a conductor, whose sectional area should be uniform to
the earth. For if it be not so, and each conductor be fully charged with
electricity, then when the sectional area diminishes there will be
congestion, resulting in heat and discharge to the building. Hence the
thickness of the main conductor must increase with the number of
separate points erected.

4. _Joints, how made._

Some are rivetted, others are screwed, others are coupled by right and
left-handed screws. Tubes are socketed into each other. In one case “the
end of the conductor is knotted and drawn through a cup-shaped ring of
metal.”

There can be no doubt that joints are the greatest source of danger in
lightning conductors. If a joint be imperfect, and the conductor be
conveying a charge to earth, heat will be generated there, the conductor
may be fused and rendered useless, and the discharge will be diverted to
the building. Or the joint may be so bad—that is, its resistance may be
so great—that it renders the conductor practically useless, for other
parts of the building will offer easier paths to the earth. Though the
use of solder is pretty general, it is not universal. Indeed, one
manufacturer objects to it because “it must interfere with surface
conduction!” It certainly should be imperatively used. No joint can
possibly be perfect that is not metallically continuous. Careful
soldering is the only certain mode of securing this, and that this is
practicable is evident from the millions of perfect joints in telegraph
wires. To scrape the ends of wire bright, and cover the whole with thin
sheet lead, as is done by one firm, is simply to court danger. The
absence of joints in wire rope is one great element in its favour.

5. _Attachment to building, how made._

Some attach the conductor to the building by copper straps and nails;
some use holdfasts, either of copper wire or gun metal; others use
staples; one uses metallic ties. Several pass the conductor through
insulators of glass, porcelain, or earthenware. But the majority discard
insulators as useless.

In the opinion of the writer they are quite right, for it is difficult
to understand what useful function the insulator performs. One fact that
occurred in 1837 is given as a reason for their use, but the fact
militates against the efficiency of the conductor rather than the
absence of insulators. If the conductor were perfect there could have
been no concussion at the point of attachment. If it were imperfect
there may have been, for the discharge would seek other paths to earth.
Some manufacturers use holdfasts of a different metal to that of the
conductor. This is wrong, for where different metals are used galvanic
action sets in, tending to decay and rupture. The attachments for this
reason should always be of the same metal as the conductor.

6. _Ground connection, how formed, and of what extent._

The necessity for reaching moist ground is generally recognised, but
various curious ways for making earth connection are suggested. One firm
considers that a band cut into strips 18 inches long would suffice,
while another says that not less than 30 feet, in two or three branches,
with fork at the end of each band, should be used. One firm is very
brief: “Ground end is coiled loosely in damp earth or a well.” The use
of coke, powdered charcoal, or carbonaceous materials, is insisted upon
by others.

It is questionable whether the difficulty of fitting a good connection
with the earth is fully realized. None but telegraphists know the great
difficulty there is in doing this. The first object to be secured is a
good damp soil, and the next as large a conducting surface as possible.
Metal pumps, iron, gas, or water pipes, wells in which plates of metal 2
or 3 feet square are placed, or similar plates may be buried in
perpetually damp ground, or in holes well filled with powdered coke.
Moisture in some form is essential, and without it a lightning protector
is of small service.

7. _Extent of area supposed to be protected._

The majority of the firms consider that the area protected has a radius
equal to the height of the conductor; but one firm considers that this
should be multiplied by five or six times; while another asserts, “that
no appreciable extent is protected by a single rod conductor;” and
another, that “many instances may be related of buildings being struck
much within the radius of well protected churches or chimneys.”

We have no experience at present to enable us to form a definite opinion
on this point. The Committee of the French Academy, gave the radius as
equal to twice the height of the conductor from the ground, but
buildings have undoubtedly been injured within this limit. The writer
does not think that a greater radius than the height should be taken:
but thinks that this is one of the most important questions that the
Conference could determine. Calculation might, to a certain extent,
settle the point: but it is more a case for experience.

8. _If there is more than one terminal, is the size of the conductor
increased?_

This question has been partially considered. (See No. 3.)

* * * * *

Some firms do not consider any increase necessary: others think that
when two or more terminals are used, the main rope should be somewhat
enlarged; while others run one cable from each terminal, or make the
conductor of sufficient capacity to carry off the double charge.

The writer considers that every conductor should be complete in itself:
or, if this is inconvenient, then the size of the main conductor should
be enlarged in proportion. It does not at all follow, as one firm
implies, that if two or more terminals receive the charge
simultaneously, it is necessarily sub-divided. Each charge may be full
and complete in itself, and be sufficient to fill the wire; and,
therefore, if the main conductor be not increased, accident may result.

* * * * *

There is no doubt whatever that great consideration should always be
given to the lessons of experience, and the opinions of those who have
made the erection of lightning conductors for 35 years their especial
practical study, are much entitled to weight; but such practice may have
originally been based on error, and the teachings may not have been
guided by science. Where such variety of practice abounds, there must be
fallacy somewhere, and, therefore, danger; and not the least of the
beneficial labours of the Conference will be to point out to these
different practical men, where their faults and their departures from
truth exist.

W. H. PREECE.

_August 8th, 1879._

APPENDIX C.

REPLY FROM MANUFACTURERS, RECEIVED AFTER THE COMPLETION OF THE ANALYSIS
WHICH FORMS APPENDIX B.

FARADAY STEAM WORKS,
ST. JOHN’S ROAD, HUDDERSFIELD.
_11th November, 1879._

SIR,

Enclosed we have pleasure in handing you our replies to the eight
questions which you ask lightning rod manufacturers and erectors,
together with three tracings, showing our system of protection under
different conditions. In the case of Nottingham Castle we considered
it necessary, on account of the rock on which the castle was built,
to adopt an extensive system of lateral points in earth termination,
by running all the main conductors from the building down the
shrubbery into the moat, where we formed the flat copper band into
the form of gridirons, in which several hundred feet of the copper
band has been used, and the termini of the ribs pointed, and the
whole being sunk eight feet, and two cart-loads of gas carbon laid
over each grid.

Yours obediently,
SANDERSON & CO.

REPLIES TO THE QUESTIONS OF THE LIGHTNING-ROD CONFERENCE.

I.—Usually a length of copper tube 5 feet long 1 inch diameter × No. 8
B.W.G., which is termed the elevation rod, surmounted by a solid copper
point, forged from ⅞th of an inch round bar, wrought three parts of its
length to a square tapering point, the said elevation rod and point are
screwed together by a copper ball-shaped union, into which are screwed
four smaller points at an angle of 45 degrees. When fixing lightning
conductors on church spires and turrets we usually run the copper tape a
few inches above the vane or finial, having previously prepared and
pointed the tape; by this system all joints are avoided.

II.—We, the sole inventors, manufacture the solid copper tape lightning
conductors of the following siz

source: Project Gutenberg · page

Cite this

"Lightning Rod Conference". Project Gutenberg. Public domain in the USA. https://www.gutenberg.org/ebooks/58367

JSON record · API collection · BibTeX · RIS · CSL-JSON · citation policy

Save to pass ·